| Offer Type: |
BUY |
| Post Date: |
Jun.19,2008 |
| Expired Date: |
Oct 18, 2008 |
| Category: |
Electrical Equipment & Supplies |
EMD 20 645E4 Diesel Generators with synchronous generators We have received a purchase option on 3 generators. The information on the two portable unit is what follows. The third unit is a stationary G.E. turbine Generator that is a frame 5 unit - Type P - generates 17 MW - Operates on gas or oil - Unit was purchased new and is 20 years old. If interested, can provide photos and information. Location is in same facility as the following generators that we are trying to market. Attached are photos of the control room area and inside one of the two generators. Information received and taken is as follows: The information reported : Mfgr: General Electric - Electric Motive Division - La Granda, Illinois Model: A-20-C Volts: 2400/4160 KVA: 3250 RPM: 900 Cycle: 60 Hours: 2262 Starts: 1057 Information received from Plant Watch Engineer How big are these two units: 2.5 MW each Independent of turbine generator and/or boiler Condition: (Opinion): Based upon appearance and age, both units: good Another name for these two units is "Peekers" Nameplate Information - Other than what has already been reported: Diesel Motor: Serial #: 69-K1-1159 Synchronous Generator: Serial #: 69 - K1 - 1100 Frame: 9 Powered by General Motors Amps: 782/452 KVA Peaking Rate: 3575 Power Factor: 0.8-Excitation Volts:144-Amps: 100 Unit built in the year: 2000 Hours/1 year: 2000 Temperature Rise: 85 Degrees C - Stator - Therm 105 " C - Stator - Therm In closing, it is my opinion that priority is going to be given by dismantling company to those offering that will be based upon "as is - where is". Units are located in Florida , and arrangements can be made for inspection. Time is of the essence. Commitment will be made by end of the month. Area where units sit now is going to be needed for dismantling material from inside the plant. The data received a few days ago on this particular equipment with regards to outage: A) Hours run since last Overhaul: 6,061.65 Total number of Starts: 731 Gross MWH Produced: 114,716 Date: Last Overhaul Started: 2/19/2000 Date Last Overhaul Completed: 7/11/2000 Number of Generator trips: 2 Boroscope Examination - very recent Waiting for Satisfactory written report B) Information received from Plant Operation Supervisor: 1) Unit is designated a F-5 2) New unit purchased new in 1990.Acquisition Cost: Over 30 Million 3) Rated Capacity: 25 MW - Has been operating at 20 - 21 MW 4) Complete Package including Boiler C) Nameplate Data: Gas Operated turbine Unit G.E. Generator - air cooled Number - Category: 335 x 844 Poles: 2 - Phase: 3 WYECONN - Cycle: 60 Max. cold air temperature: 15 Degrees C. KVA: 33700 Max. KVA: 35900 Armature Amps: 1410 Max. Armature amps: 1502 Armature volts: 13800 Max. Armature Volts: 13800 Field amps: 244.4 Max. Field amps: 260 Excitation Volts: 250 Max. Excitation Volts: 250 Power factor: 0.90 Max. Power Factor: 0.90 RPM: 3600 Max. RPM: 3600 G.E. Turbine: Turbine Number: 295352 Base: K 22830 Turbine Exhaust: 924 Degrees F CPR SR Stages: 17 RPM: 5100 Air Intake: 90 degrees F Alt: SL Fuel: Distilled Oil Pressure: 12" H 2 O Turbine Stages: 2 A second nameplate was used on turbine portion. All Categories were Ditto as noted above with exception of: Fuel: Natural Gas Base: K 22520