Product Categories

TKR-400A Computerized High-Frequency Ventilator For Infant

TKR-400A  Computerized High-Frequency Ventilator For Infant
Category:
Price:
USD 3500.00 - 8000.00
Brand:
TELI
Model:
TKR-400A
Port:
any port in china
Delivery Lead Time:
about 2 weeks
Packaging:
carton
Payment Terms:
  • Western Union
  • T/T
  • L/C
Minimum Order:
1 Set(s)
Supply Availability:
100 Set(s) per Month

Product Description

The ventilator adopts opening ventilation mode with high frequency and little quantity of tidal air, so the airway pressure is low and it has less effect on blood stream recycling to heart, the resisting force is also small when breathing.With its function of pressure supporting, the ventilator is good to increase the consumption of the function of patients respiratory muscle. The ventilator also adopts the hardened tube system and the mechanical cavity is small. Especially fit for infants

Feature:
A. The tidal gas can be exported with constant pressure, contact current and accurately adjustable flow.
B. Opening ventilation, which used opening intubation without casing bag, and get little resistance when expiratory is suitable for the ventilation management of infant .
C. Evident effectiveness of ARDS treatment can be shown with inserting small tube and jetting oxygen through nasal vestibule, which is safe and doesn't cause pressure injury easily.
D.Special CPAP tube for infant ventilation treatment are available .
E.PEEP and humidifier volume can be adjusted accurately.
F. Alarm system with sound and light when no oxygen, power failure or low airway positive pressure.
G. Heated humidifier can be used for good effectiveness of humidifying.
H. Inbuilt storage battery, it can be used while being charged and can be used for more than four hours after full charged .
Main Technique Parameter :
Frequency:10~150 breaths/min
I/E ratio:1:1~ 1:3 and inverse ratio
Driving Pressure :0~60KPa
Humidifying rate :6ml/h
Process Ventilation:T=10min,
ProI: T1(150bpm):T2(35bpm)=7:3
ProII: T2(35bpm): T1(150bpm)=7:3
Storage Battery: 4Ah, 12V, Rechargeable
SIGH:3breaths/min
Alarm:Alarm with sound and light when lack of power,or the airway pressure is overy 1Kpa0.2Kpa and alarm will last for 6 seconds when no oxygen.
CPAP:0.1~0.8KPa
PEEP:0.1~0.5KPa
Oxygen Concentration :21%-90%(with air compressor) ; 40%-90%(with trolley)
Ventilation Mode:HFJV(High Frequency Jet Ventilation);CPAP