Product Description

The end-tidal carbon dioxide modules etco2 modules independently developed and produced by Kingst can be used with multi-parameter patient monitors, ventilators and anesthesia machines for monitoring of real-time ETCO2 concentration, inhaled CO2 concentration, respiratory rate, inspiratory and expiratory times.



Types of Capnography EtCO2 Module

Mainstream EtCO2 Capnography Module Capno-M

A mainstream end tidal carbon dioxide detector, it has a unique sample cell protects internal NDIR components from pollution.



Sidestream EtCO2 Capnography Sensor Capno-S

A side stream etco2 sensor, accurate and durable, suitable for various complex environments.



Mainstream EtCO2 Capnography Module Capno-M

A product that can be used for both intubated and non-intubated patients, breaking through the limitation that mainstream modules can only be used for intubated patients.



Sidestream EtCO2 Capnography Module Capno-S

A side stream EtCO2 sensor, accurate and durable, suitable for various complex environments. Compatible with multiple protocols.



Understanding Capnography EtCO2 Module

Kingst's end-tidal carbon dioxide ETCO2 modules are widely used in the operating room, ICU and emergency department, and can be used to monitor whether the position of the endotracheal intubation is correct, whether the spontaneous breathing is restored, whether the parameter settings during mechanical ventilation are reasonable, and whether the cardiopulmonary resuscitation is effective, etc. Kingst's products have the characteristics of quick response, high accuracy, good quality and stable performance.



Sidestream and Mainstream Capnography

End tidal co2 monitoring with mainstream VS side stream CO2 Sensors



Mainstream CO2 sensor

Judging the position of endotracheal intubation



On the patient'airway- quick response



There are neonatal, pediatric and adult adapters available



Side stream CO2 Sensor

Can be used for both intubated and non-intubated patients



The sensor is not directly connected in the ventilation circuit



Sampling without intubation,non-invasive monitoring



Specifications of Capnography EtCO2 Sensor

Environmental temperature 550?

Relative humidity 1090%?Non-condensing?

Atmospheric pressure 55115kpa

Power consumption 150ma

Interface and communication RS-232/ Standard E-8-1,38.4 kBaud,10 ms data interval KM Or customized according to customer requirements

Co2 Measuring range 0-150mmHg

Accuracy 040mmHg, inaccuracy?± 2mmHg?

4170mmHg, inaccuracy?±5% of Reading?

70100mmHg, inaccuracy?± 8% of Reading?

101150mmHg, inaccuracy?±10% of Reading?

Respiration Rate 2150t/min

Inaccuracy The bigger value of ±1% or ±1t/min