Price:
USD 200.00 - 400.00
Delivery Lead Time:
3-10 WORKING DAYS
Supply Availability:
100000 Pieces per Year
Product Description
Fluorescence Method Dissolved Oxygen Analyzer is based on the principle of fluorescence quenching, blue light irradiates to the fluorescent material to make the fluorescent material excitate red light, because the oxygen molecules can take away the energy quenching reaction, the time and intensity of red light and the concentration of oxygen molecules are inversely proportional. By measuring, the phase difference is excitated between the red light and the reference light, then to calculate the concentration of oxygen molecules by corresponding to the internal calibration value. By adopting innovative new fluorescent technology, no membrane and electrolyte is needed, almost no maintenance, excellent performance, easy to operate, no oxygen consumed, can be applied to any occasion, including those low water cycle.
Application
Waste water Treatment
Surface Water
Aquaculture
Features
Optical principle: no need to replace the membrane and electrolyte, no flow requirements
No signal drift, no calibration required
Using ARM system, more stable and reliable
Lattice display, Chinese and English menu
2 routes of 4-20mA current/ RS485 output
Stainless steel electrodes, more rugged and reliable
Air cleaning device is optional
Features
Technical Data
Measurement parameter
Measuring range: 0 - 20.00ppm / 0 - 200%, 0 - 60ºC
Resolution: 0.01ppm / 1%, 0.1ºC
Accuracy: ±0.1ppm or ±1%
Input Measuring sensor: innoSens 450 optical DO sensor
Output Analog Output 1:
4-20 mA isolated current output for Dissolved Oxygen, it can be made to represent any segment of the measuring scale
Load: Max 600?
Analog Output 2:
4-20 mA isolated current output for TEMP., it can be made to represent any segment of the measuring scale
Load: Max 600?
Relay 12 Alarm Operation: ON/OFF
Selectable action : High / Low
Set Point: High/10.00 ppm; Low/4.00 ppm adjustable
Hysteresis: 0.01 ppm adjustable
Relay contacts: 5A/250VAC;5A/30VDC
Relay 3 Washing Relay Wash interval: 0.11000hour
Wash time: 11000s
Relay contacts: 5A/250VAC;5A/30VDC
Interface RS 485 Modbus RTU
Baud rate: 9600 bps
Data format: 8 bit
General Information
Power supply 90 - 260V AC, 50/60Hz; 24VDCOptional
Operating temperature 0 - 60 ºC
Storage temperature -20 - 70 ºC
Humidity Max. 90% rH at 40ºC non-condensing
LCD Display Dissolved oxygen value, temperature value and relay status
Language Chinese / English
Passcode Set mode: 0022, Calibration mode: 0011
Protection grade IP65
Dimensions 160 166 73mm
Installation Wall Mounting
Weight 1Kg
Sensor Information
Type innoSens 450
Material 316L
Size Diameter 33.5 mm, length 197 mm, connection 3/4BSP
Cable 10 m
Max. Pressure 4 bar
Protection grade IP68