PACON 4800 Online Water Hardness Analyzer

PACON 4800 Online Water Hardness Analyzer
Category:
Price:
USD 2400.00 - 3400.00
Brand:
JENSPRIMA
Model:
PACON 4800
Delivery Lead Time:
7-10 days after received the payment
Packaging:
carton
Payment Terms:
  • T/T
Minimum Order:
1 Pieces
Supply Availability:
1000 Pieces per Year

Product Description

Measurement Parameters

?Total Hardness



?Total alkalinity









Applications



?Demineralized water



?Reverse osmosis



?Boiler water



?Laundry room



?Groundwater



?Cooling tower



?Pharmaceutical water



?Process water



?Drinks / food



Features



? Fully automatic measurement



According to the selected reagent, automatically measure the total water hardness in different ranges. This analysis is more efficient than manual measurements and more reliable than other indirect measurement methods such as ion-selective electrodes.









? Smart accurate



GB measurement method - Titration colorimetry method, the instrument has a calibration function. Integrated measurement techniques and two-stage analysis identify external influences such as trough contamination, watery turbidity and external light and eliminate these effects in the measurement.







? A variety of measurement modes



- Continuous measurement



- Interval measurement 5-99min



- External switch signal initiates measurement







? Compact design



The dimension is only 300x300x200mm, can be directly linked to the wall or mounted on the bracket.







? Minimum maintenance workload



Complete isolation of water and testing device, detachable measuring cell, without the need for additional tools for maintenance, can be easily implemented. It is recommended to replace the spare parts package once a year including: peristaltic pump head reagent tube, stirrer, seal, order number: 50-5000-10







? Automatic cleaning



Rinsing and Cleaning are performed automatically for each analysis, ensuring measurement accuracy, repeatability and reduced field maintenance.







?Low reagent consumption



Reagent bottle can be easily replaced, 500ml reagent can measure 5000 10000 times. Reagents valid for 2 years.











?LCD backlight LCD display



Multi-language graphics backlight LCD display measurements, reagent remaining, alarm values and relay status.











?0 / 4-20mA output









? SD card data storage



2G data storage card, can be directly imported into the computer to excel format access to historical data and system failure information.



Features

Basic parameters



Measuring principle: Titration colorimetry



Ambient temperature: 5 - 45 ?



Water temperature: 5 - 40 ?



Water sample pressure: 0.5 - 5bar, recommended 1-2bar over 2bar recommended installation of pressure reducing valve



Water quality requirements: colorless, no suspended matter, no bubble pH 4 - 10.5, iron: 3ppm, copper: 0.2ppm aluminum: 0.1ppm, manganese: 0.2ppm



In / out connection: OD 6mm hose



Humidity: 20 - 90% RH, indoor installation



Power supply: 85 - 265VAC, 47-63Hz, 25VA runtime



Size / Weight: 300 x 300 x 200mm, ca. 4Kg with outer case



Protection class: IP65









Technical Data



Measuring range: 0.53 - 534.0 ppm CaCO3 see reagent type



Measurement time: About 3 minutes, depending on water hardness and set rinse time



Accuracy: ± 5% of the upper limit of the selected reagent



Repeatability: The upper limit of the selected reagent ± 5%



Analysis cycle: continuous measurement / interval measurement 5-99min / external start signal



Rinse time: 15 - 1800s



Water consumption: about 1000ml / analysis



Display: Backlit LCD display graphics, numerical



Optional units: mmol / L, ppm CaCO3, ° dH, ° f and so on



Current output: 0/4 - 20mA, Max. 750



Relay output: 2 passive relay output NC / NO, 250VAC 4A



Input: External switch signal start analysis